Canto II (BD) Bench-top Analyser
- triple laser     405nm violet
                        488nm Sapphire
                        633 HeNe
- 10 parameter
- cytometer for 8 (2, 4, 2) colour analysis

Performance  (Top)
Fluorescence Sensitivity FITC-A : <100 molecules of equivalent soluable fluorophore
PE-A : <50 molecules of equivalent soluable fluorophore
Fluorescence Resolution < 3% for PI labelled chick erythrocyte nuclei
Forward and Side
Scatter Sensitivity
Sensitivity enables the separation of fixed platelets from noise, identification of bacteria and 0.5 micron beads
Forward and Side
Scatter Resolution

FSC 1.0µm

SSC 0.5µm
 Acquistion rate max 10,000 events/second(1x107 cells/ml @ 120ul/min)

Excitation Optics  (Top)
Optical Platform Fixed optical assembly on cuvette flow cell

Lasers

Air cooled

30mW 407nm
20mW 488nm,
17mW 635nm,

Emission Optics  (Top)
Optical Coupling Quartz cuvette is coupled to emission lens by refractive index matching optical gel for optimum collection efficiency

Laser steering delivers spacially separated beams to flow cell

Fixed fiber apertures (125um separation)
Fluorescence detectors High performance, high dynamic range photomultipliers and red-sensitive photomultipliers with filters
405nm
Fluorescence Detectors and Filters
450/50nm     PB/BV 421/Alexa 405/V450
525/5nm       BV 470/Qd 525/V500 /KO
488nm
Fluorescence Detectors and Filters 
525/30nm      FITC/Alexa-488/GFP/CFSE
585/42nm      PE/DsRED
670LPnm       PerCP/PE-Cy5/7AAD
780/60nm     PE-Cy7
635nm
Fluorescence Detectors and Filters
661/20nm       APC/Alexa-647
780/60nm       APC-Cy7/APC-Alexa-750

Fluidics  (Top)
General Operation Integrated fluidics cart and compressor with onboard housekeeping solutions for automated startup, shutdown, and cleaning cycles
Fluid Reservoirs Easily accessible 20L capacity sheath and waste containers ; level detectors automatically indicate low levels of sheath or high levels of waste
Sample Flow Rates Flow rates of 120µL/min(HI), 60µL/min(MED), and 10µL/min(LOW).
Regulated pressure difference between sheath and sample
Quartz Cuvette Internal cross-section is rectangular 430 x 180-µm; external surfaces are anti-reflection coated for maximum transmission of laser light
Sample Concentration Single-cell suspension of 105 to 2 x 107 particles/mL recommended range

Signal Processing  (Top)
Workstation Resolution 262,144 linear channels displayed in a 5 log decade display(18bit)
Data Acquisition Channels 10 parameters- 8 colour and 2 scatter
Fluorescence Compensation Networks Inter- and intra-beam software programmable resolution of 0.01%
Pulse Processing Width, Height and Area measurements for discriminating doublets; available for all fluorescence parameters; Ratio measurements for intra-laser parameters
Time Time available correlated to any parameter for kinetic experiments or other applications.

Data Management System   (Top)
Workstation PC 
Central Processing Unit (CPU) Intel Core 2 Duo E6850 Dual-Core3 3.00-GHz, 4MB shared L2 cache, 1333 MHz FSB
Memory 2GB RAM
Software BD FACSDiva 6.1.3
Data Storage
Networking
CD ROM DVD/CD-ROM read/write combo drive
Monitor 2x19-inch MultiSync Monitors
Data File Structure Flow Cytometry Standard (FCS) 2.0 and 3.0 ASCII results file for data export